Search results for " saturation"
showing 10 items of 177 documents
Tentative Recommendation on Terminology and Definitions in Respiratory Physiology: Résumé of the Isott Consensus Session 1992
1994
1 The use of small letters for the symbols “p” (partial pressure), “s” (saturation) and “c” (concentration) (e.g. pO2, sO2, cO2) follows recommendations of the IFCC and IUPAC [4]. This supports the use of contemporary word processing systems and mostly eliminates the need to use subscripts (except for chemical valencies: e.g. O2, CO2, H2CO3 etc.). The potential risk of misinterpretations and double meanings is reduced also (e.g. “cO2” [oxygen concentration] v.s. “CO2” [carbon dioxide] and “sO2” [oxygen saturation] v.s. “sO2” [sulfur dioxide]). 2 The symbol shall include the site of measurement or description, e.g. paO2 (arterial O2 partial pressure), svO2 (mixed venous oxygen saturation), o…
Structure of longitudinal chromomagnetic fields in high energy collisions
2014
We compute expectation values of spatial Wilson loops in the forward light cone of high-energy collisions. We consider ensembles of gauge field configurations generated from a classical Gaussian effective action as well as solutions of high-energy renormalization group evolution with fixed and running coupling. The initial fields correspond to a color field condensate exhibiting domain-like structure over distance scales of order the saturation scale. At later times universal scaling emerges at large distances for all ensembles, with a nontrivial critical exponent. Finally, we compare the results for the Wilson loop to the two-point correlator of magnetic fields.
Robust l2-gain control for 2D nonlinear stochastic systems with time-varying delays and actuator saturation
2013
Abstract This paper is concerned with the problems of stability analysis and l2-gain control for a class of two-dimensional (2D) nonlinear stochastic systems with time-varying delays and actuator saturation. Firstly, a convex hull representation is used to describe the saturation behavior, and a sufficient condition for the existence of mean-square exponential stability of the considered system is derived. Then, a state feedback controller which guarantees the resulting closed-loop system to be mean-square exponentially stable with l2-gain performance is proposed, and an optimization procedure to maximize the estimation of domain of attraction is also given. All the obtained results are for…
Characterization of inductors in partial saturation for SMPS applications
2017
The exploitation of partially saturated inductors in Switching Mode Power Supply (SMPS) is a key strategy for reducing the size of SMPS and increasing their power density [1]. However an accurate characterization and modellization of each inductor is needed for a correct design and control of the SMPS [2]. Most of inductors' datasheets only indicate the nominal inductance at low current. Anyway, when the inductor is subjected to a higher current, the value of the inductance is lessened. Moreover, inductance meters often actuate their measurements at no or moderate DC bias. In this work we describe the realization of an automated test bench (Fig. 1) for characterizing an inductor under varia…
Biotic and abiotic soil properties influence survival of Listeria monocytogenes in soil
2013
International audience; Listeria monocytogenes is a food-borne pathogen responsible for the potentially fatal disease listeriosis and terrestrial ecosystems have been hypothesized to be its natural reservoir. Therefore, identifying the key edaphic factors that influence its survival in soil is critical. We measured the survival of L. monocytogenes in a set of 100 soil samples belonging to the French Soil Quality Monitoring Network. This soil collection is meant to be representative of the pedology and land use of the whole French territory. The population of L. monocytogenes in inoculated microcosms was enumerated by plate count after 7, 14 and 84 days of incubation. Analysis of survival pr…
The oxygen status of arterial human blood
1990
The oxygen status of arterial human blood is described at least by four variables: Oxygen partial pressure (pO2, mmHg), oxygen saturation (sO2, %), hemoglobin content (cHb, g/dL) and oxygen content (cO2, mL/dL). Beside perfusion, however, the oxygen supply of all organs is decisively determined by the mean capillary pO2 which itself is primarily dependent on the arterial cO2. Therefore, the oxygen availability (cardiac output x caO2, mL/min) may be described by the cO2 value in arterial blood or those variables who determine the latter one. The diagnostic significance of the O2 variables of the oxygen status consequently increases in the order of pO2, sO2 (cHb) and cO2. In arterial blood, o…
Evolution of fluctuations in the initial state of heavy-ion collisions from RHIC to LHC
2019
Fluctuations in the initial state of heavy-ion collisions are larger at RHIC energy than at LHC energy. This fact can be inferred from recent measurements of the fluctuations of the particle multiplicities and of elliptic flow performed at the two different energies. We show that an analytical description of the initial energy-density field and its fluctuations motivated by the color glass condensate (CGC) effective theory predicts and quantitatively captures the measured energy evolution of these observables. The crucial feature is that fluctuations in the CGC scale like the inverse of the saturation scale of the nuclei.
Abnormal thyroid hormones and non-thyroidal illness syndrome in obstructive sleep apnea, and effects of CPAP treatment
2016
Objective In obstructive sleep apnea (OSA), while both hypothyroidism and hyperthyroidism have been studied, the occurrence of non-thyroidal illness syndrome (NTIS) (normal thyroid stimulating hormone [TSH] with low triiodotironine) has not been investigated. We explored the occurrence of NTIS in patients with moderate to severe OSA and its relationship to the severity of nocturnal respiratory disorders. We also studied the occurrence of subclinical hypothyroidism (SH, ie, high TSH with normal thyroxine) in OSA and changes in circulating TSH, free triiodotironine (fT3) and free thyroxine (fT4) after CPAP treatment. Methods After a nocturnal respiratory polysomnography, 125 consecutive patie…
ERT and IPT surveys to check the integrity of the geomembrane in the landfill of Bellolampo (Palermo, Italy)
2016
In landfills, changes in resistivity and chargeability can be related to the characteristics of the waste and they can be abrupt and considerable within short distances. These physical properties are function of generation, mobility and degree of saturation of the leachate, gas generation, compaction density and variability. These relationships mean that it can be possible to get an overall image of the quantity and characteristics of the waste from surface electrical measurements over the landfill. In this paper, we present and discuss the results of three electrical tomographies carried out in the landfill site of Bellolampo (Palermo, Italy). The main aim of these surveys was to check the…
Closed-Loop Automatic Oxygen Control (CLAC) in Preterm Infants: A Randomized Controlled Trial
2014
BACKGROUND AND OBJECTIVE: In preterm infants receiving supplemental oxygen, routine manual control (RMC) of the fraction of inspired oxygen (FIO2) is often difficult and time consuming. We developed a system for closed-loop automatic control (CLAC) of the FIO2 and demonstrated its short-term safety and efficacy in a single-center study. The objective of this study was to test the hypothesis that this system is more effective than RMC alone in maintaining arterial oxygen saturation within target levels when evaluated over 24 hours under routine conditions and with different target levels. METHODS: We performed a multicenter, randomized controlled, crossover clinical trial in 34 preterm infa…